30 research outputs found

    The TRILL project: increasing the technological readiness of Laue lenses

    Full text link
    Hard X-/soft Gamma-ray astronomy (> 100 keV) is a crucial field for the study of important astrophysical phenomena such as the 511 keV positron annihilation line in the Galactic center region and its origin, gamma-ray bursts, soft gamma-ray repeaters, nuclear lines from SN explosions and more. However, several key questions in this field require sensitivity and angular resolution that are hardly achievable with present technology. A new generation of instruments suitable to focus hard X-/soft Gamma-rays is necessary to overcome the technological limitations of current direct-viewing telescopes. One solution is using Laue lenses based on Bragg's diffraction in a transmission configuration. To date, this technology is in an advanced stage of development and further efforts are being made in order to significantly increase its technology readiness level (TRL). To this end, massive production of suitable crystals is required, as well as an improvement of the capability of their alignment. Such a technological improvement could be exploited in stratospheric balloon experiments and, ultimately, in space missions with a telescope of about 20 m focal length, capable of focusing over a broad energy pass-band. We present the latest technological developments of the TRILL (Technological Readiness Increase for Laue Lenses) project, supported by ASI, devoted to the advancement of the technological readiness of Laue lenses. We show the method we developed for preparing suitable bent Germanium and Silicon crystals and the latest advancements in crystals alignment technology.Comment: arXiv admin note: text overlap with arXiv:2211.1688

    The large area detector onboard the eXTP mission

    Get PDF
    The Large Area Detector (LAD) is the high-throughput, spectral-timing instrument onboard the eXTP mission, a flagship mission of the Chinese Academy of Sciences and the China National Space Administration, with a large European participation coordinated by Italy and Spain. The eXTP mission is currently performing its phase B study, with a target launch at the end-2027. The eXTP scientific payload includes four instruments (SFA, PFA, LAD and WFM) offering unprecedented simultaneous wide-band X-ray timing and polarimetry sensitivity. The LAD instrument is based on the design originally proposed for the LOFT mission. It envisages a deployed 3.2 m2 effective area in the 2-30 keV energy range, achieved through the technology of the large-area Silicon Drift Detectors - offering a spectral resolution of up to 200 eV FWHM at 6 keV - and of capillary plate collimators - limiting the field of view to about 1 degree. In this paper we will provide an overview of the LAD instrument design, its current status of development and anticipated performance

    IDeF-X HD: A CMOS ASIC for the Readout of Cd(Zn)Te Detectors for Space-Borne Applications

    No full text
    International audienceIDeF-X HD is a 32-channel analog front-end with self-triggering capability optimized for the readout of 16×16 pixels CdTe or CdZnTe pixelated detectors to build a low power micro-gamma camera. IDeF-X HD has been designed in the standard AMS CMOS 0.35μm process technology. Its power consumption is 800μW per channel. The energy range of the ASIC can be extended to 1.1MeV thanks to the in-channel adjustable gain stage. When no detector is connected to the chip and without input current, a 33 electrons rms ENC level is achieved after shaping with 10.7μs peaking time. Spectroscopy measurements have been performed with CdTe Schottky detectors. We measured an energy resolution of 4.2keV FWHM at 667keV (137Cs) on a single-pixel configuration. Meanwhile, we also measured 562eV and 666eV FWHM at 14keV and 60keV, respectively (241Am) with a 256 small pixel array and a low detection threshold of 1.2keV. Since IDeF-X HD is intended for space-borne applications in astrophysics, we evaluated its radiation tolerance and its sensitivity to single event effects. We demonstrated that the ASIC remained fully functional without significant degradation of its performances after 200 krad and that no single event latch-up was detected putting the linear energy transfer threshold above 110MeV/(mg/cm2). Good noise performance and radiation tolerance make the chip well suited for X-rays energy discrimination and high energy resolution. The chip is space qualified and flies on board of the solar orbiter ESA mission launched in 2020

    Low Energy Characterization of Caliste HD, a Fine Pitch CdTe-Based Imaging Spectrometer

    No full text
    International audienceCaliste HD is a recently developed micro-camera designed for X and gamma-ray astronomy, based on a 1×1 cm2^2 CdTe Schottky pixelated detector. Its entire surface is composed of 256 pixels, disposed on a 16 × 16 pixel array. This spectrometer is buttable on its 4 sides and can be used to create a large focal plane. It is also designed for space environment. Its IDeF-X front-end electronics has low power consumption, excellent noise performance and a wide dynamic range, from 2 keV to 1 MeV. Moreover, electronic noise performances of this device were optimized to set the low level energy threshold lower than 2 keV.This paper focuses on the Caliste HD performance near the low energy limit. For this purpose, we have exposed the CalisteHD module to a mono-energetic X-ray beam, and set energies between 2 and 12 keV. We measured accurately the detectionefficiency in this energy range and found it to be ranging from 39% to 75% for energies from 2.2 keV to 11.6 keV, consideringonly particles detected in the single-event photopeak and ignoring events impinging between two adjacent pixels. Thisefficiency detection profile thereby highlights crucial effects of the Pt electrode opacity on Caliste HD low energy response, andsuggests the presence of absorption zones at the interface between CdTe crystal and platinum. Respective thickness of eachlayer were estimated by simulation and confirmed by RBS (Rutherford Backscattering SpectroscopyRutherford\ Backscattering\ Spectroscopy).Besides, using a mono-energetic beam allows fine energy resolution measurement, which was found to be ranging from560 to 760 eV FWHM between 2 and 12 keV. In addition, the linearity of this spectrometer and the issue of charge sharingbetween adjacent pixels were studied. This study revealed that spectroscopic performances remain excellent for such boundaryoperating conditions
    corecore